Osmomat auto Freezing point osmometer

The design of the Osmomat auto is based on ten years of experience with the measuring principle of the Osmomat 030.

We have been able to automate the draining of the measuring system so that it is possible to reliably obtain a high sample throughput. The simple menu-driven operation requires a minimum of user interaction and allows an automated operation of the Osmomat.

Advantages

  • minimum user involvement via fully automatic measurement of up to 20 samples
  • simple and fast
  • small sample volume: 50 µL standard sample volume
  • easy calibration
  • measuring time: approximately 70 seconds per single measurement
  • disposable plastic measuring vessels save time and money
  • menu-driven operation
  • automatic error detection: display shows clear error message
  • sample data can be entered by means of a barcode reader
  • measurement documentation by means of an integrated printer
  • three different print versions with different information are possible, depending on the system configuration
  • constant stand-by mode allows operation over a long period of time

Key data

Sample volume
50 µl
Test time
approximately 70 seconds
Reproducibility
<±1.0 %
Display
LCD-display, 4 lines with 20 digits
Measuring range
0 up to 2500 mOsmol/kg
Resolution
1 mOsmol/kg over the entire range
Crystallization process
by inoculation of the sample with ice crystal
Cooling
Peltier-cooling system with heat dissipation by air
Ambient temperature
10 °C - 30 °C

Measurement: Freezing point osmometer

Freezing point osmometer

The total osmolality of aqueous solutions is determined by comparative measurements of the freezing points of pure water and of solutions. Whereas water has a freezing point of 0 °C, a solution with saline concentration of 1 Osmol/kg has a freezing point of -1.858 °C.

Applications

The Osmomat auto solves your problem when a large number of samples must be measured. This unit is employed when routine measurements in the medical sector or in industry and research are required. The Osmomat auto can determine the total osmolality of aqueous solutions when small sample volumes are available or a short measuring time is required.

General medicine
  • Routine and research
  • Forensic medicine
  • Electron microscopy
  • Physiology
  • Clinical Laboratories
  • Intensive care laboratories
  • Pediatrics
  • Gynecology
  • Invitro fertilization
  • Urology
  • Nephrology
  • Hemodialysis/Hemofiltration
  • Veterinary medicine
  • Botany
  • Pharmacy
  • Dispensaries etc.
100 mOsmol/kg calibration standard PU 10 Order No. 30.9.0100
100 mOsmol/kg calibration standard

Calibration standard 100 mOsmol/kg, suitable as control solution, can be used as an alternative to the calibration standards with 300 mOsmol/kg or 850 mOsmol/kg and can be used as a further calibration point for the Osmomat 030 with the option 3P.

300 mOsmol/kg calibration standard PU 10 Order No. 30.9.0020
300 mOsmol/kg calibration standard

Calibration standard 300 mOsmol/kg for the calibration of osmometers which can also be used for the verification of the plausibility.

Osmoref® 290 mOsmol/kg reference solution

Reference solution Osmoref® 290 mOsmol/kg for evaluating the performance of your osmometer, irrespective of your calibration standard.

500 mOsmol/kg calibration standard PU 10 Order No. 30.9.0500
500 mOsmol/kg calibration standard

Calibration standard 500 mOsmol/kg, suitable as control solution, can be used as an alternative to the calibration standards with 300 mOsmol/kg or 850 mOsmol/kg and can be used as a further calibration point for the Osmomat 030 with the option 3P.

850 mOsmol/kg calibration standard PU 10 Order No. 30.9.0850
850 mOsmol/kg calibration standard

Calibration standard 850 mOsmol/kg, suitable as control solution, can be used as an alternative to the calibration standard with 300 mOsmol/kg or can be used as a further calibration points for the Osmomat 030 with the option 3P.

2000 mOsmol/kg calibration standard PU 10 Order No. 30.9.2000
2000 mOsmol/kg calibration standard

Calibration standard 2000 mOsmol/kg, suitable as control solution, can be used as an alternative to the calibration standards with 300 mOsmol/kg or 850 mOsmol/kg and can be used as a further calibration point for the Osmomat 030 with the option 3P.

Measuring vessels for OSMOMAT auto PU 1000 Order No. 35.9.0010

Gonotec measuring vessels are constantly controlled and grant thus the expected reproducibility of the measuring results.

Cleaning paper for OSMOMAT auto PU 1 Order No. 35.9.1030

Original Gonotec cleaning paper.

Printer paper PU 8 Order No. 30.9.1010

Original Gonotec rolls of printer paper

Original Gonotec Thermistor probe, 50 µl sample volume